150°C Rated
1" SRO 250°C Rated
2- ¼" SRO 350°C Rated
2- ¼" Memory 400°C Rated
2- ¼" Memory P/T Sonde
1" - 2-¼" PLT System Components - compatible with 3rd party tools (at lower cost)
Interfacing software for both memory and SRO tools. A competent, simple to use system that allows the gathering of data for later transfer into 3rd party analysis packages.
200°C Rated
1-11/16" (43mm) Standard high-reliability cablehead for mono to four conductor cables.
320°C Rated
1-11/16" (43mm) High temperature version of the standard cablehead, mono to four conductor cables
Custom Heads
Custom designs for larger cables and more conductors can be produced.
Weakpoints
In the standard cableheads only the outer armour is gripped to create the weakpoint. Options are available to install a fully engineered titanium tensile weakpoint with full calibration certificates.
The standard depth system uses a 0.5m circumference measuring wheel with a hardened and ground rim for accuracy and durability. Measurement data is recorded both electronically and mechanically thus
ensuring continuous depth data in the event of an electronic system fault. Aimed primarily at geothermal logging the unit is not currently zone rated
Clamped and grouted, electronic and fibre optic based
Not strictly a product as each application tends to require custom design, the standard building blocks of downhole HPU's are established. These can either be pumped from surface with downhole intensification or self
contained electric motor/pump systems with or without further intensification. Pressures in excess of 35,000psi can be achieved.
A range of calipers exist to suit different applications. X-X
Developed to measure the internal profile of downhole valves and inflow control devices the X-X caliper makes two independent radial measurements in the same plane. In addition measurements of well pressure and temperature are made to assist with depth correlation. The standard tool is coiled tubing conveyed and records the data into non volatile memory for later download using Pro-Log.
X-Y
A conventional X-Y caliper for openhole, geothermal applications, 300°C rated. 2-¼" diameter
4, 6, 8 Arm
Multiple independent arm calipers, housing diameters up to 3 3/8" (86mm), 300°C rated
Low temperature, <80°C, high definition, fibre optic based transmission system for use in subsea and riser inspection.
A 200°C rated, high definition camera is in development (patented).
Production Logging tools
Pressure, Temperature, Gamma, Spinner, CCL, Water-cut, Fluid conductivity
1" Memory
1-11/16"
2- ¼" Memory
Knuckle Joints
3 Arm Centraliser
4 Arm Centraliser
Flowmeter heads
Pro-Log Logging Software
Cableheads - High Reliability model
Depth System
Seismic Receivers
Hydraulic Power Units
Calipers
Sub Sea Riser Camera
High Temperature Camera